RS-NAGV |
|
|
Emergency
stop |
|
|
and safety gate monitoring relay |
|
|
CE, TÜV, UL, C-UL |
|
|
6 normally open
safety, 4 normally auxiliary closed |
|
|
Opposite
polarity between channels |
|
|
Cyclial
monitoring of the function |
|
|
LED indicators for
status and supply diagnostic |
|
|
Channel
1 and channel 2 |
|
|
24 V AC / DC (without galvanic disconnection/
safety resistor) |
|
|
24 V DC (without
galvanic disconnection / electronic fuse), |
|
|
24, 110-127, 230 V AC (with galvanic
disconnection/transformer) |
|
|
ca. 6 VA |
|
|
< 200 ms / ca. 30 ms |
|
|
4 A, 240 V AC, 60 V DC |
|
|
10 mA |
|
|
Simultaneous
protective door contacts : ca. 75 ms |
|
|
- 25°C to + 55°C |
|
|
1000 VA (resistive load), 120 W |
|
|
4 A quick acting |
|
|
|
|
(*)
We offer all devices who have a CONTACT CAPACITY of min. 100 mA at 24 V DC with hard
gold-plated contacts. In this way the CONTACT CAPACITY of min. 100 mA is only 4 mA. Please
ask our sales team!
|
A
supply voltage must be applied at terminals A1 and A2 in order to operate the
device. If this is done there is a voltage of 24V DC at terminals T11, T12
and T22 must be wired as shown in the application examples. To start the unit
terminal T11 must be bridged with terminal T34 by means of a closing contact
or terminal T34 must receive a 24V DC impulse (short time bridging of the connection
terminals T11-T34). If this is done contacts 13-14, 23-24, 33-34, 43-44,
53-54 and 63-64 close and 71-72, 81-82, 91-92 and 101-102 open. The LEDs channel 1 and channel 2 illuminate. Through terminal
X1 and X2 the function of an external
contactor can be monitored. Terminals X1 and X2 must be bridged in order to
operate the device.
|
|
|
|
|
Safety
relevant substance data Depending
on wiring (only max. values are given) |
EN ISO 13849-1: PLe,
Cat.4 MTTFd: 74,61 years / high, DC: 99% / high CCF:
achieved |