RS-NAGU.1 / RS-NAGU.2f |
|
|
Muting
control |
|
|
RS-NAGU.1 : CE, TÜV,
UL, C-UL, |
|
|
RS-NAGU.2f : CE, UL,
C-UL |
|
|
RS-NAGU.1: 3 electr. Safety semicond. outp. / RS-NAGU.2 f: 3 normally
open |
|
|
4 muting sensors connectable |
|
|
Control of filament
of external muting lamp |
|
|
pushbutton |
|
|
Power indication,
channel 1, channel 2, fault and restart interlock |
|
|
|
|
|
24 V DC |
|
|
|
|
|
10 W (up to 60W including peripheral devices
) |
|
|
RS-NAGU.1 : < 6
ms -
RS-NAGU.2f : < 20 ms |
|
|
RS-NAGU.1 : 0,7 -
1,5 A(*2), 24 V DC / RS-NAGU.2f : 3,5 - 6 A(*3), 24 V
AC/DC |
|
|
RS-NAGU.1 : 1 mA /
RS-NAGU.2f: 100 mA(*) |
|
|
Simultaneous of the
muting sensors : 3 s |
|
|
- 25°C to + 55°C |
|
|
NAGU.1 : 17 W, NAGU.2f: 84 W |
|
|
RS-NAGU.1 : outputs are permanently short
circuit proof |
|
|
RS-NAGU.2f :4 A
quick acting or 3,15 A time lag |
|
(*)
We offer all devices who have a CONTACT CAPACITY of min. 100 mA at 24 V DC with hard
gold-plated contacts. In this way the CONTACT CAPACITY of min. 100
mA is only 4 mA. Please
ask our sales team!
|
NAGU
is used for muting of safety light barriers and safety light curtains, so
that material - transport to or from a machine can be done. Applications can
be found in the automotive industry, packaging machines or at highly
automated production systems. The differentiation between human beings and
material flow is done with up to four muting sensors or two safety light
barriers. Inductive sensors or mechanical switches can also be used as muting
sensors. After connection as per application guide, the device will be ready
as soon as the power LEDīs and channel 1 and
channel 2 are illuminated. If LEDīs channel1/2 are blinking, a fault exists or a wrong connection has
been made. In ready condition the RS-NAGU can be started by pushing the start
key. If it cannot be started, then at least one of the muting sensors is
blocked or not connected correctly. If a muting sensor is blocked by material
supply, a muting can be initiated by actuation of the key switch. If the
light barrier is interrupted after a muting cycle, RS-NAGU can be activated by pushing
the start key after the failure has been fixed. As
soon as muting sensors 1 and 2, respectively 3 and 4 will be activated within
3 sec., the RS-NAGU will initiate a muting cycle. Muting takes place so long
the inputs of both groups of muting sensors are in active state plus 0,25s
time-delay. RS-NAGU.1:
3 electronic safety semiconductor outputs. RS-NAGU
2f: 3 normally open safety, 3 normally open signal outputs (release, and safety light
barrier) RS-NAGU
(housing with detachable terminal strips) also this unit is available |
|
|
(*) We offer all devices which have a contact
capacity of min. 100 mA at 24 VDC with hard
gold-plated contacts. In this way you get a contact capacity of 4 mA. (*2) 1,5 A permanent current (1 output) up to
4,5 A peak current (t<1s,UV>21,6V), 1
A permanent current (2outputs), 0,7 A permanent current (3 outputs) (*3) 6 A permanent current (1 output), 3,5 A
permanent current (3 outputs) Notice: please ask for detailed documentation. |
|
Safety
relevant substance data Depending
on wiring (only max. values are given) |
EN ISO 13849-1: PLe,
Cat.4 MTTFd: >100 years / high, DC: 99% / high, CCF:
achieved |