Two hand control relays

            DEVICE

SAFE Z.2

 

Two hand control relay

 

                APPLICATIONS

for type I-III c

 

                APPROVALS

CE, TÜV, UL, C-UL

 

                CONTACTS

2 normally open safety, 1 normally auxiliary closed, 1 PLC-output

 

               

LED indicators for status and supply diagnostic

 

                SPECIAL CHARACTERISTICS

Two hand control relay according ZH 1 / 456 and DIN EN 574

 

 

 

                LED

Power, channel 1 and channel 2

 

               

24 V AC / DC (electronic fuse)

 

                OPERATING VOLTAGE

48, 115, 230 V AC (with galvanic disconnection / transformer)

 

               

 

                POWER CONSUMPTION

ca. 2 VA

 

                START UP DELAY / FALLBACK TIME

< 50 ms / < 25 ms

 

                CONTACT CAPACITY max.

6 A, 250 V AC, 24 V DC

 

                CONTACT CAPACITY min. at 24V DC (*)

6 mA

 

                SIMULTANEITY

Simultaneous: 0,5s

 

                ENVIRONMENTAL TEMPERATURE

- 25 °C to + 55 °C

 

                SWITCHING CAPACITY

1500 VA (resistive load)

 

                CONTACT SECURITY

6,3 A quick acting or 4 A time lag

 

               

 

 

 

 

                OPERATING MODE

                (*) We offer all devices who have a CONTACT

                 CAPACITY of min. 100 mA at 24 V DC with

                 hard gold-plated contacts. In this way the

                 CONTACT CAPACITY of min. 100 mA is only 4 mA.

                Please ask our sales team!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                CONNECTION DIAGRAM

After supply voltage was applied to terminals A1 and A2, the SAFE Z will be ready for operation. The power LED illuminates. If the button S1 is pressed and within 0,5 sec. the button S2 also pressed, the outputs 13-14,  23-24 are closed and 31-32 will be opened. The machine will be started. The PLC-output (34) is connected with 24 V supply voltage. If one or both buttons are released, the outputs 13-14 and 23-24 open immediately. The output 31-32 closes. Only after releasing of both buttons S1 and S2, a new cycle can be started. If the time for pressing the buttons S1 and S2 will be longer than 0,5 sec., the outputs were not released. The outputs 13-14 and 23-24 keep open. The machine cannot be started. On the terminals Y1 and Y2 machine release circuit (repeating contactor control) or a bridge can be connected.

 

For version with detachable clamps (screw - or cage clamps) ...

please ask our sales team!

Still available: RS-NAGZ with an additionally auxiliary contact. For further information please see the manual or   www.automation-safety.com

 

 

 

 

 

 

 

                FUNCTION CIRCUIT DIAGRAM

 

                Certifications according to

                Safety relevant substance data

                Depending on wiring (only max. values are given)

EN ISO 13849-1: PLe, Cat.4

MTTFd: 36,45 years / high, DC: 99% / high, 

CCF: achieved