SAFE Z |
|
|
Two
hand control relay |
|
|
for type I-III c |
|
|
CE, TÜV, UL, C-UL |
|
|
2 normally open
safety, 1 normally auxiliary closed |
|
|
LED indicators for
status and supply diagnostic |
|
|
Two hand control
relay according ZH 1 / 456 and DIN EN 574 |
|
|
|
|
|
Power, channel 1 and channel 2 |
|
|
|
|
|
24 V DC (electronic fuse) |
|
|
|
|
|
ca. 3 VA |
|
|
< 50 ms
/ < 30 ms |
|
|
6 A, 250 V AC, 24 V DC |
|
|
1 mA |
|
|
Simultaneous:
0,5 s |
|
|
- 25 °C to + 55 °C |
|
|
1500 VA (resistive load) |
|
|
6 A quick acting or
4 A time lag |
|
|
|
|
(*)
We offer all devices who have a CONTACT CAPACITY of min. 100 mA at 24 V DC with hard
gold-plated contacts. In this way the CONTACT CAPACITY of min. 100
mA is only 4 mA. Please
ask our sales team!
|
After
supply voltage was applied to terminals A1 and A2, the SAFE Z.2 will be ready
for operation. The power LED illuminates. If the button S1 is pressed and
within 0,5 sec. the button S2 is also pressed, the
outputs 13-14, 23-24 are closed and
31-32 will be opened. The machine will be started. If one or both buttons are
released, the outputs 13-14 and 23-24 open immediately.The
output 31-32 closes. Only after
releasing the both buttons S1 and S2, a new cycle can be started. If the time
for pressing the buttons S1 and S2 will be longer as 0,5
sec., the outputs were not released. The outputs 13-14 and 23-24 keep open.
The machine cannot be started. On the terminals Y1 and Y2 machine release
circuits (repeating contactor control) can be connected.
|
|
|
|
|
Safety
relevant substance data Depending
on wiring (only max. values are given) |
EN ISO 13849-1: PLe,
Cat.4 MTTFd: 36,85 years / high, DC: 99% / high,
CCF:
achieved |