Download User Manual in PDF

 

            DEVICE

SAFE M / SAFE M.1

 

Mat and contact edges control relay with a max. mats-resistance

                APPLICATIONS

of 200 ohms

                APPROVALS

CE, TÜV, UL, C-UL

 

                CONTACTS

3 normally open safety, 1 normally auxiliary closed

 

               

LED indicators for status and supply diagnostic

 

                SPECIAL CHARACTERISTICS

Opposite polarity between chanels

 

 

With (SAFE M) and without (SAFE M.1) automatic start

 

                LED

Power, channel 1 and channel 2

 

               

 

 

                OPERATING VOLTAGE

24 V AC / DC (electronic fuse)

               

SAFE M: 115 V AC (with galvanic disconnection/transformer)

 

                POWER CONSUMPTION

24, 115 V AC: ca. 5 VA, 24 V DC: 3 W

 

                START UP DELAY / FALLBACK TIME

<  50 ms / <  30 ms (24 V AC <  50 ms)

 

                CONTACT CAPACITY max.

5 A, 240 V AC, 24 V DC

 

                CONTACT CAPACITY min. at 24V DC (*)

6 mA

 

                SIMULTANEITY

 

                ENVIRONMENTAL TEMPERATURE

-25°C to + 55°C

 

                SWITCHING CAPACITY

1200 VA (resistive load)

 

                CONTACT SECURITY

6,3 A quick acting (normally open) or 4 A time lag (normally closed)

 

               

 

 

 

 

                OPERATING MODE

                (*) We offer all devices who have a CONTACT

                 CAPACITY of min. 100 mA at 24 V DC with

                 hard gold-plated contacts. In this way the

                 CONTACT CAPACITY of min. 100 mA is only 4 mA.

                Please ask our sales team!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                CONNECTION DIAGRAM

A supply voltage must be applied to terminals A1 and A2. Power LED illuminates and 24V DC is available at terminal S11. Terminals S12 and S22 must be connected according to the application example selected to meet the application requirements. To start the unit terminals S33 and S34 must be bridged with a normally open contact. The unit works if you close this contact. At this time the contacts 13-14, or bridge for automatically start  23-24 and 33-34 are closed. The LEDs channel 1 and channel 2 illuminate. In series to this start button an external contactor can be controlled.   

For automatic start (SAFE M only) the terminals S33 and S34 must be brigded. The safety mats and safety bars must be of 4 wire technology or 2 wire technology and have to agree to the cross circuit principle.

 

For version with detachable clamps (screw - or cage clamps) ...

please ask our sales team!

 

 

 

 

 

 

 

 

 

                FUNCTION CIRCUIT DIAGRAM

 

                Certifications according to

                Safety relevant substance data

                Depending on wiring (only max. values are given)

EN ISO 13849-1: PLe, Cat. 3

MTTFd: 73,21 years / high, DC: 90% / medium,   CCF: achieved

PFH: 5,81*10-9 1/h,  SFF: 99%