Multifunctional |
|
|
|
SAFE FLEX |
|
|
Safety
controller |
|
|
with
choosable multi functions |
|
|
CE, TÜV, UL, C-UL |
|
|
2 normally open, 1 PNP output |
|
|
LED indicators for
status and supply diagnostic |
|
|
optical failure
indication by LEDs |
|
|
Automatic start possible |
|
|
Power, channel 1
IN/OUT, channel 2 IN/OUT, failure |
|
|
24 V DC ( + 20 - 25 % ) |
|
|
Overvoltage
protection |
|
|
|
|
|
< 3 W |
|
|
e-stop,BWS, Two hand,safety gate
monitoring relay <= 30ms |
|
|
6 A, 250 V AC, 250 V DC |
|
|
5 mA |
|
|
depending on the choosen functionality (see technical data) |
|
|
- 25°C to + 55°C |
|
|
1500 VA |
|
|
6 A quick acting or
4 A time lag |
|
|
|
|
(*)
We offer all devices who have a CONTACT CAPACITY of min. 100 mA at 24 V DC with hard
gold-plated contacts. In this way the CONTACT CAPACITY of min. 100
mA is only 4 mA. Please
ask our sales team!
|
By
wiring the following functionality is are choosable: -
E-Stop safety controller cat. 4 - safety gate controller cat. 4 -
Two-Handed safety controller cat. 3c -
ESPE safety controller (light barriers and curtains) cat. 4 and cat.2 - single pole safety devices with cyclic testing cat. 4 Wiring
changes during operation are not allowed and lead to a failure message.
|
|
|
|
|
Safety
relevant substance data Depending
on wiring (only max. values are given) |
EN ISO 13849-1/ EN 62061: PLe, Cat. 4 / SIL3 MTTFd: >100 years / high, DC: 99% / high, CCF: achieved PFH:
2,15*10-9 1/h, SSF: 94,65% |