Two hand control relays |
|
|
|
SAFE CZ |
|
|
Two
hand control relay |
|
|
for
type IIIc or II |
|
|
CE, (TÜV, UL, C-UL pending) |
|
|
4 OSSD |
|
|
LED indicators for
status and supply diagnostic |
|
|
wearless contacts, "AND" function between several SAFE C possible, |
|
|
automatic start possible |
|
|
Power, channel 1 and channel 2 |
|
|
24 V DC ( + 25 - 20 % ) |
|
|
Overvoltage
protection |
|
|
|
|
|
ca. 3 W |
|
|
< 100 ms / < 25 ms |
|
|
total current bis 1,8 A |
|
|
infinite |
|
|
0,5 s |
|
|
-25°C to +55°C |
|
|
to 43 W |
|
|
short
circuit proof |
|
|
|
|
(*)
We offer all devices who have a CONTACT CAPACITY of min. 100 mA at 24 V DC with hard
gold-plated contacts. In this way the CONTACT CAPACITY of min. 100
mA is only 4 mA. Please
ask our sales team!
|
In
use of the application below the simultaneousness of both switches is
monitored (less than 0,5 s). This behaviour
corresponds to EN 954-1 safety category 4. This
application is suitable for type II of DIN EN 574 and corresponds to EN 954-1
safety category 3. Wiring
changes during operation are not allowed and lead to a failure message. Application
corresponds to EN 954-1 type IIIc and safety
category 4, EN IEC 62061 up to SIL3 and EN ISO 13849-1 up to PLe.
|
|
|
|
|
Safety
relevant substance data Depending
on wiring (only max. values are given) |
EN ISO 13849-1/ EN 61508: PLe, Cat. 4 / SIL3 MTTFd: 163 years / high, DC:
high, CCF: achieved
PFH: 2,87*10-9 1/h, PFD: 2,01*10-6 1/h, SFF: 0,9573 |