Emergency stop and safety gate monitoring
relays with time-delay function |
|
|
|
SAFE T… |
|
|
Emergency stop and safety gate monitoring relay
with immediate and |
|
|
delayed outputs |
|
|
CE, TÜV, UL, C-UL |
|
|
2 n.o., 2 n.o. start up delayed, 1 n.c. |
|
|
cross circuit
protection or single-channel |
|
|
Time delay 0,05s -
600s in 64 steps, |
|
|
automatic or
manually start with start button |
|
|
Power, channel 1,
cannel 2, channel 1 and channel 2 time-delayed |
|
|
|
|
|
24 V AC / DC ( + 25
- 20 % ) (electronic fuse ) |
|
|
|
|
|
ca. 4,8 W |
|
|
< 400ms / < 30 ms / adjustment |
|
|
6 A , 250 V AC, 24 V DC |
|
|
6 mA |
|
|
SAFE TN: 1s / SAFE
TA,TR: 3s / TU: infinite |
|
|
- 25°C to + 55°C |
|
|
1500 VA (resistive load) |
|
|
3,6A |
|
|
|
|
(*)
We offer all devices who have a CONTACT CAPACITY of min. 100 mA at 24 V DC with hard
gold-plated contacts. In this way the CONTACT CAPACITY of min. 100 mA is only 4 mA. Please
ask our sales team!
|
When
releasing E-Stop button or opening the safety gate (E-Stop circuit are open)
the contacts 13-14 and 23-24 (outputs) open. The contacts 47-48/57-58 open
delayed at the adjusted time. SAFE
TN standby time after applying of the
supply voltage < 0,95 s. Opening of the
E-Stop circuits meanwhile results to failure. SAFE
TA standby time after applying of the
supply voltage < 0,95 s. Opening of the E-Stop circuits meanwhile
results to several activations of the outputs
after the standby time. SAFE
TR restart is possible during standby
time. SAFE
TU standby time after applying of the
supply voltage < 0,95 s. Opening of the E-Stop circuits meanwhile
results to several activations of the outputs
after the standby time.
|
|
|
|
|
Safety
relevant substance data Depending
on wiring (only max. values are given) |
EN ISO 13849-1 / EN 62061: PLe, Cat. 4 / SIL3,
SIL CL3 PFH: 3,4*10-9 1/h,
PFD: 9,32*10-6 1/h, SFF: 94% MTTFd: >100 years / high, DC: 99% / high, CCF: achieved |