Control devices for safety light barriers |
|
|
|
SAFE L.2 |
|
|
Emergency
stop relay |
|
|
for
safety light curtains / barriers |
|
|
CE, TÜV, UL, C-UL |
|
|
3 normally open safety |
|
|
LED indicators for
status and supply diagnostic |
|
|
Without
opposite polarity between channels |
|
|
start control choosable by a extern bridge |
|
|
Power, channel 1,
channel 2 and restart interlock |
|
|
|
|
|
24 V DC (electronic fuse) |
|
|
|
|
|
ca. 2,5 W |
|
|
< 50 ms
/ < 30 ms |
|
|
6 A, 250 V AC, 24 V DC |
|
|
10 mA |
|
|
Simultaneous:
ca. 40ms |
|
|
- 25 °C to + 55 °C |
|
|
1500 VA (resistive load) |
|
|
6 A quick acting or
4 A time lag |
|
|
|
|
(*)
We offer all devices who have a CONTACT CAPACITY of min. 100 mA at 24 V DC with hard
gold-plated contacts. In this way the CONTACT CAPACITY of min. 100
mA is only 4 mA. Please
ask our sales team!
|
A
supply voltage must be applied to terminals A1 and A2. The "Power"
and "restart interlock" LEDīs illuminate.
If this is done, a voltage of 24 V DC is be
available on the terminal S11. Terminals S12 and S22 must be wired as shown
in the application examples. To start the module, the terminals Y1 and Y2
must be bridged over normally open contact. In the following the contacts
13-14, 23-24 and 33-34
are closed. The
LEDīs of channel 1, channel 2 are
illuminate and "restart interlock" must be switched off. In series
to the start-button, wired on terminals Y1 and Y2, an external contactor can
be controlled. Monitoring of the reset circuit can be configured by external
bridge between terminals BR1 an BR2. For
version with detachable clamps (screw - or cage clamps) ... please ask our sales team!
|
|
|
|
|
Safety
relevant substance data Depending
on wiring (only max. values are given) |
EN ISO 13849-1: PLe,
Cat.4 MTTFd: 36,16 years / high, DC: 99% / high,
CCF:
achieved |