Control devices for safety light barriers

            DEVICE

SAFE L.2

 

Emergency stop relay

 

                APPLICATIONS

for safety light curtains / barriers

 

                APPROVALS

CE, TÜV, UL, C-UL

 

                CONTACTS

3 normally open safety

 

               

LED indicators for status and supply diagnostic

 

                SPECIAL CHARACTERISTICS

Without opposite polarity between channels

 

 

start control choosable by a extern bridge

 

                LED

Power, channel 1, channel 2 and restart interlock

 

               

 

                OPERATING VOLTAGE

24 V DC (electronic fuse)

 

               

 

                POWER CONSUMPTION

ca. 2,5 W

 

                START UP DELAY / FALLBACK TIME

< 50 ms  /  < 30 ms

 

                CONTACT CAPACITY max.

6 A, 250 V AC, 24 V DC

 

                CONTACT CAPACITY min. at 24V DC (*)

10 mA

 

                SIMULTANEITY

Simultaneous: ca. 40ms

 

                ENVIRONMENTAL TEMPERATURE

- 25 °C to + 55 °C

 

                SWITCHING CAPACITY

1500 VA (resistive load)

 

                CONTACT SECURITY

6 A quick acting or 4 A time lag

 

               

 

 

 

 

                OPERATING MODE

                (*) We offer all devices who have a CONTACT

                 CAPACITY of min. 100 mA at 24 V DC with

                 hard gold-plated contacts. In this way the

                 CONTACT CAPACITY of min. 100 mA is only 4 mA.

                Please ask our sales team!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                CONNECTION DIAGRAM

A supply voltage must be applied to terminals A1 and A2. The "Power" and "restart interlock" LEDīs illuminate. If this is done, a voltage of 24 V DC is be available on the terminal S11. Terminals S12 and S22 must be wired as shown in the application examples. To start the module, the terminals Y1 and Y2 must be bridged over normally open contact. In the following the contacts 13-14, 23-24 and 33-34  are closed.

The LEDīs of channel 1, channel 2 are illuminate and "restart interlock" must be switched off. In series to the start-button, wired on terminals Y1 and Y2, an external contactor can be controlled. Monitoring of the reset circuit can be configured by external bridge between terminals BR1 an BR2.

 

For version with detachable clamps (screw - or cage clamps) ...

please ask our sales team!

 

 

 

 

 

 

 

 

                FUNCTION CIRCUIT DIAGRAM

 

                Certifications according to

                Safety relevant substance data

                Depending on wiring (only max. values are given)

EN ISO 13849-1: PLe, Cat.4

MTTFd: 36,16 years / high, DC: 99% / high, 

CCF: achieved