Download User Manual in PDF

 

            DEVICE

SAFE 1 / SAFE 1.1

 

Emergency stop

 

                APPLICATIONS

and safety gate monitoring relay

 

                APPROVALS

CE, TÜV, UL, C-UL

                CONTACTS

3 normally open safety, 1 normally auxiliary closed

 

               

LED indicators for status and supply diagnostic

 

                SPECIAL CHARACTERISTICS

 

 

With (SAFE 1.1) and without (SAFE 1) start control

 

                LED

Power, channel 1 and channel 2

 

               

 

 

                OPERATING VOLTAGE

24 V AC / DC (electronic fuse)

               

 

                POWER CONSUMPTION

ca. 2,5 VA / 2,5 W

 

                START UP DELAY / FALLBACK TIME

<  50 ms  /  <  100 ms

 

                CONTACT CAPACITY max.

5 A, 250 V AC, 24 V DC

 

                CONTACT CAPACITY min. at 24V DC (*)

1 mA

 

                SIMULTANEITY

 

                ENVIRONMENTAL TEMPERATURE

-25°C to + 55°C

 

                SWITCHING CAPACITY

1250 VA (resistive load)

 

                CONTACT SECURITY

6,3 A quick acting or 4 A time lag

 

               

 

 

 

 

                OPERATING MODE

                (*) We offer all devices who have a CONTACT

                 CAPACITY of min. 100 mA at 24 V DC with

                 hard gold-plated contacts. In this way the

                 CONTACT CAPACITY of min. 100 mA is only 4 mA.

                Please ask our sales team!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                CONNECTION DIAGRAM

A supply voltage must be applied via emergency stop button to terminals A1 and A2. Power LED illuminates if the emergency stop is closed. To start the unit terminals Y2 and Y1 must be bridged with a normally open contact. The unit works if you close this contact. At this time the contacts 13-14, 23-24 and 33-34 are closed, contact 41-42 is opened. The LEDs channel 1 and channel 2 illuminate. In series to this start button an external contactor can be monitored.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                FUNCTION CIRCUIT DIAGRAM

 

                Certifications according to

                Safety relevant substance data

                Depending on wiring (only max. values are given)

EN ISO 13849-1: PLd, Cat. 3 (***see product-navigator page 4)

MTTFd: 37,57 years / high, DC: 90% / medium, 

CCF: achieved